95.99999
Conthos 3F
CONTHOS 3F TCD process gas analyzer
Base unit - field housing version
(appropriate measuring ranges must be ordered separately)
Technical data:
* Corrosion- and temperature- resistant TC-detector with SiOx-coated
Platinum sensor filaments
* Power supply: 100-240 VAC / 50-60 Hz
* Housing: purged steel housing with separate compartments for the
electronic components and the
analytical components.
* Dimensions (HxWxD): approx. 434 x 460 x 270 mm
* Protection class: IP65
* Display: backlit graphical LCD with alphanumerical + bar graph
representation
* User interface: in English and German language (switchable)
* 2 Analog outputs: 0(4)-20 mA (configurable; isolated)
* Self-diagnosis: Individual alarms are displayed in plain-text in the LC-
display and are available as
collective floating alarm contacts for remote query (28V max.; 350mA
max.): FAILURE, MAINTENANCE
REQUIRED & FUNCTION CHECK (NAMUR NE 107 compliant)
* Sample gas lines: PTFE/PFA
* Sample gas connectors: Swagelok® (SS 316) for tubing o.d. 6 mm
* Purge gas connectors: Swagelok® for tubing o.d. 6 mm
CONTHOS 3F TCD process gas analyzer
Base unit - field housing version
(appropriate measuring ranges must be ordered separately)
Technical data:
* Corrosion- and temperature- resistant TC-detector with SiOx-coated
Platinum sensor filaments
* Power supply: 100-240 VAC / 50-60 Hz
* Housing: purged steel housing with separate compartments for the
electronic components and the
analytical components.
* Dimensions (HxWxD): approx. 434 x 460 x 270 mm
* Protection class: IP65
* Display: backlit graphical LCD with alphanumerical + bar graph
representation
* User interface: in English and German language (switchable)
* 2 Analog outputs: 0(4)-20 mA (configurable; isolated)
* Self-diagnosis: Individual alarms are displayed in plain-text in the LC-
display and are available as
collective floating alarm contacts for remote query (28V max.; 350mA
max.): FAILURE, MAINTENANCE
REQUIRED & FUNCTION CHECK (NAMUR NE 107 compliant)
* Sample gas lines: PTFE/PFA
* Sample gas connectors: Swagelok® (SS 316) for tubing o.d. 6 mm
* Purge gas connectors: Swagelok® for tubing o.d. 6 mm
Available options:
* Stainless steel piping of analyzer (SS 321)
* Sample gas connectors: Swagelok® (SS 316) for tubing o.d. 1/4"
* Purge gas connectors: Swagelok® for tubing o.d. 1/4"
* Measuring ranges: up to 3 switchable, configurable ranges
* Static & dynamic interference correction
* Analog input board: 3 channels; 0(4)-20 mA
* Digital I/O interface: 8x digital inputs; 7x digital outputs
* Serial interface: RS485 with Modbus RTU protocol
===============================
NOTE 1: The CONTHOS-TCD utilizes the principle of thermal
conductivity. This inherently non-selective
principle is ideally suited to binary gas mixtures. For gases with multiple
components it is necessary to
consider the various gases comprising the sample, as well as dynamic
fluctuations in their concentrations.
These considerations can help to provide a basis for defining a reference
gas and the appropriate method of interference correction.
NOTE 2: The customer must ensure that the sample gas is dry and free
of particulates.
NOTE 3: Unless otherwise specified the CONTHOS gas analyzer is
neither ex-proof nor intrinsically safe in
terms of explosion protection.
The CONTHOS should not be used for measuring ignitable gas mixtures.
The customer must ensure compliance with applicable regulations when
using the analyzer with
inflammable or toxic gases or when installing within explosion
endangered environments.
* Stainless steel piping of analyzer (SS 321)
* Sample gas connectors: Swagelok® (SS 316) for tubing o.d. 1/4"
* Purge gas connectors: Swagelok® for tubing o.d. 1/4"
* Measuring ranges: up to 3 switchable, configurable ranges
* Static & dynamic interference correction
* Analog input board: 3 channels; 0(4)-20 mA
* Digital I/O interface: 8x digital inputs; 7x digital outputs
* Serial interface: RS485 with Modbus RTU protocol
==============================
NOTE 1: The CONTHOS-TCD utilizes the principle of thermal
conductivity. This inherently non-selective
principle is ideally suited to binary gas mixtures. For gases with multiple
components it is necessary to
consider the various gases comprising the sample, as well as dynamic
fluctuations in their concentrations.
These considerations can help to provide a basis for defining a reference
gas and the appropriate method of interference correction.
NOTE 2: The customer must ensure that the sample gas is dry and free
of particulates.
NOTE 3: Unless otherwise specified the CONTHOS gas analyzer is
neither ex-proof nor intrinsically safe in
terms of explosion protection.
The CONTHOS should not be used for measuring ignitable gas mixtures.
The customer must ensure compliance with applicable regulations when
using the analyzer with
inflammable or toxic gases or when installing within explosion
endangered environments.
JCT 95.99999 Conthos 3F CONTHOS 3F TCD process gas analyzer
- Product Code: 95.99999 Conthos 3F CONTHOS 3F TCD process gas analyzer
- Availability: In Stock
- availability : 3-8 week
- price : send inquiry
-
$0.00
- Ex Tax: $0.00
Enquire now for a quick price
Tags: JCT, 95.99999, Conthos 3F, CONTHOS 3F TCD process gas analyzer, 100-240 VAC, 50-60 Hz, 434 x 460 x 270 mm, IP65, 0(4)-20 mA, 28V max, 350mA max, SS 316, 6 mm, 1/4", SS 321, 0(4)-20 mA,